How compressible
is the human
genome sequence?
A living observatory of lossless human DNA sequence compression. Exploring the limits of information representation on the complete human reference genome.
Open benchmark · Replication scripts availableCompression landscape
Best result by compressor
Time vs. compression
Reduction relative to 2-bit baseline
Global leaderboard
| Rank ↕ | Compressor ↕ | Bytes ↕ | Bits / symbol ↕ | Time (min) ↕ | RAM (GB) ↕ | Reduction | Replication | Date ↕ |
|---|
Date: reported benchmark result date (YYYY-MM-DD). A dash indicates that the date has not been reported.
Reproducibility & methodology
Reference sequence
Benchmark of lossless compression on the DNA symbol sequence derived from T2T-CHM13 v2.0 (Nurk et al., 2022). Consult the repository for exact preprocessing, replication scripts and experimental conditions.
Replication protocol ↗Nurk, S. et al. (2022). The complete sequence of a human genome. Science, 376(6588), 44–53.
doi:10.1126/science.abj6987 ↗
Ranking criterion
Only configurations with a published replication script are included. The compressor binary must not exceed 10 MB, and the decompressor binary must not exceed 1 MB. Peak RAM usage must not exceed 32 GB during either compression or decompression, and peak disk space usage must not exceed 50 GB. Configurations are ranked by exact compressed bytes. Bits per symbol and reduction are recalculated from the benchmark sequence length.
reduction (%) = 100 × (1 − bps / 2)
Experimental comparability
All new submissions will be independently benchmarked on the same designated Linux machine, for both compression and decompression, to ensure consistent and comparable resource measurements. Distributed execution across multiple machines is not permitted. Historical results may have been obtained on different systems and will require re-evaluation under this protocol. Missing values remain unavailable.
Benchmark data
Results are embedded directly in this HTML document. Eligibility requires a published replication script, a compressor binary no larger than 10 MB, a decompressor binary no larger than 1 MB, a maximum of 32 GB RAM during each operation, and a maximum of 50 GB disk space. New results can be added by updating the embedded data.
Source repository ↗Submit a new benchmark entry
Push the limits of genome compression.
To submit a new entry, send an email to pratas@ua.pt with the three required files. All submissions will be evaluated on the same designated Linux machine. Both executables and the replication script must run locally on that machine without relying on additional machines. Submissions must comply with the scientific protocol above, including the 10 MB compressor binary and 1 MB decompressor binary size limits, 32 GB maximum RAM for both compression and decompression, and 50 GB maximum disk space usage.
Submit by email- 01Compressor binaryThe Linux executable used to compress the reference sequence (maximum 10 MB).
- 02Decompressor binaryThe Linux executable used to reconstruct the original sequence losslessly (maximum 1 MB).
- 03Replication scriptThe exact commands and parameters needed to run compression and decompression on a single Linux machine and reproduce the result within the RAM and disk space limits.